ESeal Liner Saves Mississippi Lime Well from P&A

Summary:

A large independent Operator discovered several leaks and a parted section in the 7 in. production casing from 2,000 ft. to 500 ft. In order to fracture the well, casing integrity had to be restored to handle over 6,000 psi surface fracture pressure to ensure the well could become a viable asset. The well had 7 in. production casing to 5,000 ft. then 5½ in. production liner to TD at 10,000 ft.

Download

Overview
Document Type
Case History
Date Published
Friday, February 1, 2013
Region
North America, USA, OK
Additional Document Information
Environment:
Land
System Type:
ESeal, ESeal Liner
Values Added:
Restore production, Maximize ID and TD, Maximize production, Extended well life
Casing Size:
7"
Expandable Size:
5 1/2"
Liner Length:
>3001