Summary:

Multinational Energy Company Equinor experienced damage to the 18-5/8 in. casing at approximately 740m (2,428 ft.) MD in a well on the Oseberg B field in the North Sea. The client required a repair solution that would cover the damaged section while providing post-expanded drift ID of at least 16 in. to allow for a conventional 16 in. drilling BHA needed to drill the next section of the well.

Download

Overview
Document Type
Case History
Date Published
Thursday, December 27, 2018
Region
Europe, Norway

Additional Document Information

Environment:
Shelf
System Plan:
Planned-Contingency
System Type:
ESeal, ESeal Liner
Values Added:
Enable planned completion, Reduce well cost, NPT reduced
Casing Size:
18 5/8"
Expandable Size:
16"
Liner Length:
<250'